Rating: 3785 LPM, 285 psi (19.7 bar, 1965 kPa)
Flange: 6″
Meter Construction: Steel Case, Aluminum Element
Seals: Buna/Viton® as noted by catalog number
Maximum Pressure: 285 psi (as listed by catalog number)
Temperature: -40° to 185° F
| Meter Classes | Description | Bearing Material | 
|---|---|---|
| 1 | Refined petroleum products | Ni-Resist* | 
| 16 | Alternative fuels and solvents | Carbon | 
*carbon bearings are standard on some meter sizes of this class, please consult factory.
| 
 MSAA120A1 METER LESS REGISTER AND GEAR PLATE  | 
||||||
| 
 CATALOG NUMBER  | 
 FLOW  | 
 UNIT OF MEASURE  | 
 SEALS  | 
 TEMP. COMP.  | 
 W&M APPROVAL  | 
|
| 
 MECHANICAL REGISTRATION  | 
||||||
| 
 MSAA120AT1-MECH-WP#1  | 
 L-R  | 
 DEKALITRES  | 
 VITON®  | 
 YES  | 
 OIML  | 
|
*10PPR DRY REED PULSER
MSAA120P1 METER LESS REGISTER AND GEAR PLATE
| 
 CATALOG NUMBER  | 
 FLOW  | 
 UNIT OF MEASURE  | 
 SEALS  | 
 W&M APPROVAL  | 
|
| 
 LESS REGISTER AND GEAR PLATE  | 
|||||
| 
 MSAA120P1-LRG#1  | 
 L-R  | 
 WH GAL  | 
 BUNA  | 
 NIST  | 
|
MSAA120S1 METER WITH POD (PULSE OUTPUT DEVICE)
| 
 CATALOG NUMBER  | 
 FLOW  | 
 UNIT OF MEASURE  | 
 SEALS  | 
 W&M APPROVAL  | 
|
| 
 POD (PULSE OUTPUT DEVICE)  | 
|||||
| 
 MSAA120S1-POD#1  | 
 L-R  | 
 WH GAL  | 
 BUNA  | 
 NIST  | 
|
| 
 MSAA120S1-POD#2  | 
 L-R  | 
 LITRES  | 
 VITON®  | 
 OIML  | 
|
MSAA120P2 METER LESS REGISTER AND GEAR PLATE
| 
 CATALOG NUMBER  | 
 FLOW  | 
 PRESSURE  | 
 UNIT OF MEASURE  | 
 W&M APPROVAL  | 
|
| 
 LESS REGISTER AND GEAR PLATE  | 
|||||
| 
 MSAA120P2-LRG#1  | 
 L-R  | 
 285  | 
 WH GAL  | 
 NIST  | 
|
MSAA120S2 METER WITH POD (PULSE OUTPUT DEVICE)
| 
 CATALOG NUMBER  | 
 FLOW  | 
 PRESSURE  | 
 UNIT OF MEASURE  | 
 W&M APPROVAL  | 
|
| 
 POD (PULSE OUTPUT DEVICE)  | 
|||||
| 
 MSAA120S2-POD#1  | 
 L-R  | 
 285  | 
 WH GAL  | 
 NIST  | 
|
Use the chart below to determine maximum meter flow rate relative to meter bearing material and product viscosity:
If the plotted point is above the bearing material slope, you are outside the allowable pressure loss for the specified meter and bearing. You should either chose a larger meter, reduce flow rate, or consider alternative bearing materials.